File: DM8E40.PA of Disk: Disks/Working/MyProgs-22-04-07
(Source file text) 

/TEST PROGRAM FOR DM8E40 MEMORY MANAGEMENT BOARD
/       E. LOPES CARDOZO
/       WESTVRIES COMPUTER CONSULTING BV
/       RIJKSSTRAATWEG 19A
/       1969 LB HEEMSKERK
/       02510 - 43244

/SYMBOL DEFINITIONS:
SINT=6254
SUF=6274
CINT=6204
CUF=6264
RTM=6205
LTM=6235
LRM=6245
SMME=6265
CMME=6275
SKME=6215
SKMM=6225

/FOR PRODUCTION TEST DEFINE PRODUCTION:
        PRODUCTION=1

/INTERRUPT SERVICE ROUTINE:
        *0
        0
        JMP SERV

        *20
SERV,   DCA AC        /SAVE AC
        SINT          /TRAP ?
         JMP INTERR    /NO, ILLEGAL INTERRUPT
        CINT          /CLEAR TRAP FLAG
        RTM           /READ TRAP REGISTER
        DCA TRAPD      /THAT IS THE INSTR. THE HARDWARE SAW
        CLA CMA
        TAD 0
        DCA 0         /BACKUP PC
        TAD I 0               /GET TRAPPED INSTRUCTION FROM MEMORY
        CIA           /AND COMPARE TO
        TAD TRAPD      /TRAP REGISTER CONTENTS
        SZA CLA               /SHOULD BE EQUAL
         JMS TRPERR    /ERROR IN TRAP REGISTER
        TAD 0         /DID WE TRAP THE SAFETY HLT ?
        TAD (-HALT     /
        SZA CLA               /?
         CMA          /NO, SET AC=-1
        JMP I ENDTRP   /BACK TO MAIN LOOP
ENDTRP, .-1           /CONTINUATION ADDRESS

/VIRTUAL CODE SEQUENCES:
RELTST, TAD I (7000    /RELOCATION TEST; GET DATAFIELD
        JMP HALT       /EXIT FROM USER MODE

TRPTST, JMP .         /GETS IOT TO BE TESTED
        JMP .+2               /FOR CIF: ENABLE INTERRUPTS
        ION           /FOR SKON: REENABLE INTERRUPTS
HALT,   HLT           /EXIT FROM USER MODE
        JMP .         /*** IF HERE, HLT DID NOT TRAP ***

TTYTST, TAD BELL       /TEST TTY IN UNTRAPED MODE
        TLS           /SEND A BELL TO THE CONSOLE
        TSF           /WAIT TILL READY
        JMP .-1               /
IFNDEF PRODUCTION <
        CLA           / >
IFDEF PRODUCTION <
        KCC           /USED TO CLEAR THE AC
        SZA           /DIDITDO ?
         JMP .        /NO !!! *** UNTRAPPED KCC DID NOT CLA ***
        TCF           /EXIT WITH TTY FLAG CLEAR
        TSF           /DID THAT WORK ?
        SKP           /YES
        JMP .         /***TCF DID NOT CLEAR FLAG *** >
        JMP HALT       /NOW EXIT FROM USER MODE

/MD-LINE TEST:
MDTST,  DCA I (Q
        TAD I (Q
        IAC
        SZA           /TEST ALL 4096 VALUES
         JMP MDTST
        JMP HALT
Q,      0

/CDTOIF TEST ROUTINE
CDTF,   0
        6200          /CDTOIF
        CIF 0
        JMP I CDTF

/RDF TEST ROUTINE:
TSTRDF, RDF
KK,     TAD K0        /GET ACTUAL FIELD NUMBER
        JMP HALT       /GOT THROUGH

K0,     0
K1,     1
K2,     2
K3,     3
K4,     4
K5,     5
K6,     6
K7,     7

/VARIABLES, COUNTERS AND POINTERS:
COUNT,  0
COUNT1, 0
COUNT2, 0
COUNT3, 0
PTR,    0
FIELDS, 0      /NUMBER OF FIELDS AVAILABLE
AC,     0
TRAPD,  0
BELL,   207

PAGE
      JMS INIT       /SETUP FIELDS
START,  CAF
        KIE           /DISABLE KEYBOARD INTERRUPTS
LOOP0,  JMS COPY       /MOVE PAGE 0 TO ALL FIELDS
        JMS IOTTST     /STATIC TEST OF DM8E40 IOTS
        TAD FIELDS
        CIA
        DCA COUNT      /FOR ALL FIELDS
        TAD (CDF
        DCA FCDF       /SET A CDF TO EACH FIELD
LOOP1,  TAD COUNT      /
        TAD FIELDS
FCDF,   CDF 0         //CDF0, CDF10, CDF 20, ...
        DCA I (7000    //PUT THE FIELD NUMBER AT 7000
        CDF 0         //RESTORE THE DATAFIELD
        TAD FCDF       /MAKE A NEW CDF
        TAD (10
        DCA FCDF       /
        ISZ COUNT      /ALL FIELDS DONE
         JMP LOOP1     /
/NOW A SIMPLE RELOCATION TEST. WE SET UP A SEQUENCE OF
/RELOCATION AND THAN GO VIRTUAL, PICK UP THE FIELD
/CONSTANT FROM 7000 AND HLT, TO GET OUT OF USER MODE
/WE TRY TO TEST IF ALL WORDS OF THE RELOCATION RAM
/CAN TAKE ALL VALUES, AT LEAST ALL VALUES FOR WHICH
/THERE ARE FIELDS IN THE SYSTEM.
        TAD (RET1      /SETUP TRAP RETURN ADDRESS
        DCA ENDTRP     /
        TAD FIELDS     /SET UP COUNTER FOR FIELDS
        CIA
        DCA COUNT      /
LOOP2,  TAD (-10       /TEST ALL 8 WORDS OF THE RELOCATION RAM
        DCA COUNT1     /
LOOP3,  TAD (-10       /LOAD ALL WORDS OF THE RAM
        DCA COUNT2     /
LOOP4,  TAD COUNT2     /
        TAD (10               /MAKE 0, 1, 2, ...
        LRM           /SET ALL WORDS TO 0
        ISZ COUNT2     /
         JMP LOOP4     /
        TAD COUNT      /
        TAD FIELDS     /POSITIVE REAL FIELD #
        CLL RTL               /
        RAL           /SHIFT TO BITS 6-8
        TAD COUNT1     /ADD VIRTUAL FIELD #
        TAD (10               /(POSITIVE)
        LRM           /THIS SETS ONE WORD
        TAD COUNT1     /
        TAD (10               /
        TAD (100       /USER MODE+VIRTUAL DATA FIELD
        RTF           /RESTORE FLAGS
        CLA           /?!
        JMP RELTST     /JMP TO RELOCATION TEST
/RELTST MUST BE AVAILABLE IN EACH FIELD
RET1,   CLA
        TAD AC        /GET AC FROM TRAP
        CIA           /AND COMPARE TO INTENDED FIELD #
        TAD COUNT      /
        TAD FIELDS     /
        SZA CLA               /
         JMS RELERR    /RELOCATION ERROR
        ISZ COUNT1     /
         JMP LOOP3     /
        ISZ COUNT      /
         JMP LOOP2     /
/END OF RELOCATION TEST. NOW COMES THE TRAP/UNTRAP TEST
/IN EACH AVAILABLE FIELD WE TEST EACH IOT FROM THE TABLE
        TAD FIELDS     /
        CIA
        DCA COUNT      /
LOOP5,  TAD (-10
        DCA COUNT1     /ZERO THE RELOCATION RAM
LOOP6,  TAD COUNT      /
        TAD FIELDS     /
        CLL RTL
        RAL           /
        TAD COUNT1     /
        TAD (10               /MAKE ONE-TO-ONE MAPPING
        LRM           /LOAD RELOCATION MEMORY
        ISZ COUNT1     /
         JMP LOOP6     /
        TAD COUNT      /
        TAD FIELDS     /
        CLL RTL
        RAL           /
        TAD (CDF       /MAKE CDF
        DCA XCDF       /CDF TO TARGET FIELD
        TAD (TABLE     /SETP POINTER FOR IOT TABLE
        DCA PTR               /
LOOP7,  TAD I PTR      /
        DCA TRPTST     /DROP IT IN THE TRAPTEST
        TAD (RET2
        DCA ENDTRP
        TAD TRPTST     /
XCDF,   CDF           /CDF TARGET FIELD
        DCA I (TRPTST  /IN THE TARGET FIELD TOO
        CDF 0         /
        JMS UTRALL     /UNTRAP ALL DEVICE CODES
        TAD TRPTST     /GET TEST IOT AGAIN
        AND (7776      /CLEAR UNTRAP BIT
        LTM           /AND SET DM8E40 TO TRAP FOR THIS IOT
        SUF           /ENTER USER MODE
        ION           /WITH INTERRUPT ON
        JMP TRPTST     /THIS BRINGS US INTHE TARGET FIELD !
/- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
RET2,   ISZ PTR               /RETURN FROM TRAP HANDLER
        TAD I PTR      /GET TRAP/UNTRAP INDICATOR
        RAR           /BIT 11 IS XOR!
        SZL CLA               /OK ?
         JMS TERROR    /TRAP ERROR
        TAD (RET3
        DCA ENDTRP     /SET NEW RETURN POINT
        JMS TRPALL     /TRAP ALL DEVICE CODES
        TAD TRPTST
        AND (7776
        IAC           /SET UNTRBP BIT
        LTM           /
        SUF
        ION
        JMP TRPTST     /GO !

PAGE
/- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
RET3,   ISZ PTR
        TAD I PTR
        RAR           /BIT 11 DOES XOR
        SZL CLA               /OK ?
         JMS UERROR    /NO, UNTRAP ERROR
        ISZ PTR               /SELECT NEXT IOT
        TAD I PTR      /AND FETCH IT
        SZA CLA               /END OF LIST ?
         JMP LOOP7     /NO, TEST NEXT IOT
IFNDEF FYSIOL <
/FINALY, WE TEST THE CONSOLE TERMINAL WITH IT'S IOTS UNTRAPPED:
        TAD (RET4
        DCA ENDTRP
        JMS TRPALL     /TRAP ALL DEVICE CODES,
        TAD (6031      /EXCEPT FOR THE TERMINAL
        LTM
        TAD (6041      /
        LTM           /
        SUF
        ION
        JMP TTYTST     /
/- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
RET4,   CLA CLL               / >
        TAD (RET5
        DCA ENDTRP
        SUF
        ION
        JMP MDTST      /TEST ALL VALUES FOR MD DATA
/- - - - - - - - - - - - - - - - - - - - - - - - - -
RET5,   SZA CLA               /SHOULD NOT TRAP
         JMS MDERR
        JMS RDFTST     /NOW EXERCIZE RDF IN USER MODE
        ISZ COUNT      /SELECT NEXT TARGET FIELD
         JMP LOOP5     /NOT DONE YET
        JMP LOOP0      /START OVER AGAIN

COPY,   0
        TAD FIELDS
        CIA
        IAC
        SNA
         JMP I COPY    /ONLY 4K
        DCA COUNT
COPY1,  CMA
        DCA 10
        CMA
        DCA 11
        TAD COUNT
        TAD FIELDS
        CLL RAL
        RTL
        TAD (CDF
        DCA YCDF
        TAD (-200
        DCA COUNT1
COPY2,  CDF 0
        TAD I 10
YCDF,   HLT
        DCA I 11
        ISZ COUNT1
         JMP COPY2
        TAD YCDF
        AND (70
        CLL RTR
        RAR
        TAD I (KK
        DCA I (KK
        CDF 0
        ISZ COUNT
         JMP COPY1
        JMP I COPY

/STATIC IOT TST FOR DM8E40 INSTRUCTIONS:
IOTTST, 0
        TAD (IOTLST-1  /SETUP LIST POINTER
        DCA 10
        TAD I 10       /FETCH FIRST IOT
IOT1,   DCA IOTX       /
        TAD (5252      /GET A TEST PATERN IN THE AC
IOTX,   HLT           /REPLACED BY THE IOT UNDER TEST
        JMP IOT2       /IOT DID NOT SKIP
        DCA AC        /REMEBER AC AFTER IOT
        TAD I 10       /GET SKIP FLAG
        SNA CLA               /SHOULD HE HAVE SKIPPED ?
         JMS ERR1      /NO, BUT HE DID !
        JMP IOT3       /GO CHECK AC EFFECTS
IOT2,   DCA AC        /REMEMBER AC
        TAD I 10       /GET SKIP FLAG
        SZA CLA               /SHOULD HE HAVE SKIPPED ?
         JMS ERR2      /YES, BUT HE DIDN'T !
IOT3,   TAD I 10       /GET AC-CHANGED FLAG
        SNA CLA               /SHOULD AC HAVE CHANGED ?
         JMP IOT4      /NO, GO CHECK THAT
        TAD I 10       /YES, MUST AC BE CLEAR NOW ?
        SNA CLA               /
         JMP IOT5      /NO, UNDEFINED AC NOW
        TAD AC        /YES, TEST AC
        SZA CLA               /ZERO ?
         JMS ERR3      /NO, IOT DID NOT CLA !
        JMP IOT5       /DONE ALL TESTS
IOT4,   TAD AC        /IF HERE AC SHOULD NOT HAVE CHANGED
        TAD (-5252     /TEST IF STILL OK
        SZA CLA               /
         JMS ERR4      /IOT SPOILED AC
IOT5,   TAD I 10       /GET NEXT IOT
        SZA           /END OF LIST ?
         JMP IOT1      /NO, TEST NEXT IOT
        JMS I [CDTOIF  /TEST 6200
        JMP I IOTTST

PAGE
RDFTST,       0             /TEST RDF IN USER MODE
        JMS TRPALL
        TAD (RET6
        DCA ENDTRP
        TAD I (XCDF    /SET DATAFIELD TO
        CMA           /COMPLEMENT OF
        AND (70               /REAL FIELD
        TAD (CDF
        DCA KCDF
        TAD (-7
        DCA COUNT1     /CHANGE MAPPING
LOOP8,  TAD KCDF       /
        AND (70               /
        TAD COUNT1     /
        TAD (10               /
        LRM           /
        ISZ COUNT1     /
         JMP LOOP8     /
KCDF,   CDF 70
        SUF
        ION
        JMP TSTRDF
/- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
RET6,   SZA CLA               /DID RDF TRAP ?
         JMS RDFER1    /YES, ERROR
        TAD KCDF       /COMPUTE CORRECT AC
        AND (70
        MQL
        MQA
        CMA
        AND (70
        CLL RTR
        RAR
        MQA
        CIA
        TAD AC        /GET VIRTUAL AC
        SZA CLA               / ?
         JMS RDFER2    /NO, AC WAS SPOILED !
        JMP I RDFTST   /RETURN

PAGE
/ERROR MESSAGE PROCESSORS:
INTERR, CAF
        KIE
        JMS I [STRING
        TEXT /UNEXPECTED INTERRUPT/
        JMS I [CRLF
        TAD AC
        RMF
        ION
        JMP I 0

TRPERR, 0
        JMS I [STRING
        TEXT /TRAP REGISTER WRONG: (PC-1)=/
        TAD I 0
        JMS OCTOUT
        JMS I [STRING
        TEXT /, RTM=/
        TAD TRAPD
        JMS OCTOUT
        JMS I [CRLF
        JMP I TRPERR

RELERR, 0
        JMS I [STRING
        TEXT /RELOCATION ERROR, GOOD FIELD=/
        TAD COUNT
        TAD FIELDS
        JMS OCTOUT
        JMS I [STRING
        TEXT /, ACTUAL FIELD=/
        TAD AC
        JMS OCTOUT
        JMS I [CRLF
        JMP I RELERR

TERROR, 0
        TAD TRPTST
        JMS OCTOUT
        TAD I PTR
        SNA CLA
         JMP TER1
        JMS I [STRING
        TEXT / FAILED TO TRAP/
        JMP TER2
TER1,   JMS I [STRING
        TEXT /  DID  TRAP /
TER2,   JMS I [STRING
        TEXT / IN FIELD /
        TAD COUNT
        TAD FIELDS
        AND (7
        TAD ("0
        JMS TYPE
        JMS I [CRLF
        JMP I TERROR

PAGE
UERROR,       0
        TAD TRPTST
        JMS OCTOUT
        TAD I PTR
        SZA CLA
         JMP UER1
        JMS I [STRING
        TEXT / DID NOT UNTRAP/
        JMP UER2
UER1,   JMS I [STRING
        TEXT / DID UNTRAP/
UER2,   JMS I [STRING
        TEXT / IN FIELD /
        TAD COUNT
        TAD FIELDS
        AND (7
        TAD ("0
        JMS TYPE
        JMS I [CRLF
        JMP I UERROR

MDERR,  0
        JMS I [STRING
        TEXT /TRAPPED ON MEMORY DATA /
        TAD Q
        JMS OCTOUT
        JMS I [CRLF
        JMP I MDERR

ERR1,   0
        TAD I (IOTX
        JMS I [OCTOUT
        JMS I [STRING
        TEXT / WRONGLY SKIPPED/
        JMS I [CRLF
        JMP I ERR1

ERR2,   0
        TAD I [IOTX
        JMS I [OCTOUT
        JMS I [STRING
        TEXT / FAILED TO SKIP/
        JMS I [CRLF
        JMP I ERR2

ERR3,   0
        TAD I [IOTX
        JMS I [OCTOUT
        JMS I [STRING
        TEXT / FAILED TO CLEAR AC/
        JMS I [CRLF
        JMP I ERR3

ERR4,   0
        TAD I [IOTX
        JMS I [OCTOUT
        JMS I [STRING
        TEXT / SPOILED THE AC/
        JMS I [CRLF
        JMP I ERR4
PAGE

RDFER1, 0
        JMS I [STRING
        TEXT /RDF DID TRAP !/
        JMS I [CRLF
        JMP I RDFER1

RDFER2, 0
        JMS I [STRING
        TEXT /RDF RETURNED WRONG ANSWER: /
        TAD AC
        JMS I [OCTOUT
        JMS I [CRLF
        JMP I RDFER2

PAGE
TRPALL,       0             /SUBROUTINE TO SET ALL BITS
        TAD (-100      /IN THE TRAP MEMORY (EXCEPT 600X)
        DCA TRPCNT
TRP1,   TAD TRPCNT
        TAD (100       /MAKE IT POSITIVE
        CLL RAL
        RTL
        LTM           /SET TO TRAP
        ISZ TRPCNT     /DONE ?
         JMP TRP1      /NO
        TAD (6001      /UNTRAP ION FOR 6215, 6225
        LTM           /
        JMP I TRPALL   /YES, RETURN

UTRALL, 0             /SUBROUTINE TO UNTRAP ALL DEVICE CODES
        TAD (-100
        DCA TRPCNT     /
UTR1,   TAD TRPCNT
        TAD (100       /MAKE IT POTIVE
        CLL RAL
        RTL
        IAC           /SET UNTRAP BIT
        LTM
        ISZ TRPCNT     /DONE ?
         JMP UTR1      /NO
        JMP I UTRALL   /YES, RETURN

TRPCNT, 0

CDTOIF, 0      /TEST CDTOIF INSTRUCTION
        TAD FIELDS     /FOR ALL AVAILABLE FIELDS
        CIA
        DCA COUNT1     /
CDT1,   TAD COUNT1
        TAD FIELDS     /MAKE POSITIVE FIELD NUMBER
        CLL RAL
        RTL
        TAD [CIF
        DCA CDT3       /
        TAD CDT3
        CMA           /MAKE COMPLEMENTARY CDF
        AND [70
        TAD [CDF
        DCA CDT2
CDT2,   HLT           /CDF
CDT3,   HLT           /CIF
        JMS CDTF       /DO CDTOIF IN SOME FIELD
        RDF           /READ DATA FIELD
        CDF 0         /RESET DF
        CIA
        TAD CDT3       /AND COMPARE WITH PREVIOUS
        AND [70               /INSTRUCTION FIELD
        SZA CLA               /OK ?
         JMS CDTERR    /NO, CDTOIF DID NOT WORK
        ISZ COUNT1     /TRY NEXT FIELD
         JMP CDT1
        JMP I CDTOIF   /END OF TEST

CRLF,   0
        TAD (215
        JMS TYPE
        TAD (212
        JMS TYPE
        JMP I CRLF

STRING, 0
        TAD I STRING
        BSW
        JMS BYTE
        TAD I STRING
        ISZ STRING
        JMS BYTE
        JMP STRING+1

BYTE,   0
        AND (77
        SNA
         JMP I STRING
        TAD (240
        AND (77
        TAD (240
        JMS TYPE
        JMP I BYTE

OCTOUT, 0
        RAL
        JMS DIGIT
        JMS DIGIT
        JMS DIGIT
        JMS DIGIT
        CLA
        JMP I OCTOUT

DIGIT,  0
        RAL
        RTL
        DCA OCTEMP
        TAD OCTEMP
        AND (7
        TAD ("0
        JMS TYPE
        TAD OCTEMP
        JMP I DIGIT

OCTEMP, 0

PAGE
INIT, 0
        JMS I [STRING
        TEXT /HIGHEST FIELD # ? /
        KSF
         JMP .-1
        KRB
        TLS
        TSF
         JMP .-1
        AND (7
        IAC
        DCA FIELDS
        JMS I [CRLF
        JMP I INIT

CDTERR, 0
        JMS I [STRING
        TEXT /CDTOIF FAILED IN FIELD /
        TAD COUNT1
        TAD FIELDS
        AND [7
        TAD ["0
        JMS TYPE
        JMS I [CRLF
        JMP I CDTERR

TYPE,   0
        TLS
        TSF
        JMP .-1
        CLA
        KSF
        JMP I TYPE
CTRLQ,  TAD (7600
        KRS
        TAD (-7603
        SNA
        JMP I (7600
        TAD (3-23
        SNA CLA
        JMP CTRLS
        KCC
        JMP I TYPE
CTRLS,  KCC
        KSF
        JMP .-1
        JMP CTRLQ
PAGE
/THE IOT TABLE. THE FORMAT IS: IOT;SHOULD-TRAP-IF-TRAPPED;SHOULD-TRAP-
/IF-UNTRAPPED. THE TABLE ENDS WITH IOT=0

        Y=7777
        N=0000
TABLE,  6000;Y;N
        6006;N;N       /SGT
IFDEF PRODUCTION <
        6010;Y;N
        6020;Y;N
        6030;Y;N
        6040;Y;N
        6050;Y;N
        6060;Y;N
        6070;Y;N
        6100;Y;N
        6110;Y;N
        6120;Y;N
        6130;Y;N
        6140;Y;N
        6150;Y;N
        6160;Y;N
        6170;Y;N       / >
        6200;Y;Y       /CDTOIF
        6201;Y;N       /CDF 0
        6202;Y;N       /CIF 0
        6203;Y;N       /CDF CIF 0
        6204;Y;Y       /CINT
        6205;Y;Y       /RTM
        6206;Y;Y
        6207;Y;Y
        6210;Y;Y
        6211;Y;N       /CDF 10
        6212;Y;N       /CIF 10
        6213;Y;N       /CDF CIF 10
        6214;N;N       /RDF
        6215;Y;Y       /SKME
        6216;Y;Y
        6217;Y;Y
        6220;Y;Y
        6221;Y;N       /CDF 20
        6222;Y;N       /CIF 20
        6223;Y;N       /CDF CIF 30
        6224;N;N       /RIF
        6225;Y;Y       /SKMM
        6226;Y;Y
        6227;Y;Y
        6230;Y;Y
        6231;Y;N       /CDF 30
        6232;Y;N       /CIF 30
        6233;Y;N       /CDF CIF 0
        6234;Y;Y
        6235;Y;Y
        6236;Y;Y
        6237;Y;Y
        6240;Y;Y
        6241;Y;N       /CDF 40
        6242;Y;N       /CIF 40
        6243;Y;N       /CDF CIF 40
        6244;Y;Y
        6245;Y;Y
        6246;Y;Y
        6247;Y;Y
        6250;Y;Y
        6251;Y;N       /CDF 50
        6252;Y;N       /CIF 50
        6253;Y;N       /CDF CIF 50
        6254;Y;Y
        6255;Y;Y
        6256;Y;Y
        6257;Y;Y
        6260;Y;Y
        6261;Y;N       /CDF 60
        6262;Y;N       /CIF 60
        6263;Y;N       /CDF CIF 60
        6264;Y;Y
        6265;Y;Y
        6266;Y;Y
        6267;Y;Y
        6270;Y;Y
        6271;Y;N       /CDF 70
        6272;Y;N       /CIF 70
        6273;Y;N       /CDF CIF 70
        6274;Y;Y
        6275;Y;Y
        6276;Y;Y
        6277;Y;Y
IFDEF PRODUCTION <
        6300;Y;N
        6310;Y;N
        6320;Y;N
        6320;Y;N
        6330;Y;N
        6340;Y;N
        6350;Y;N
        6360;Y;N
        6370;Y;N
        6400;Y;N
        6410;Y;N
        6420;Y;N
        6430;Y;N
        6440;Y;N
        6450;Y;N
        6460;Y;N
        6470;Y;N
        6500;Y;N
        6510;Y;N
        6520;Y;N
        6530;Y;N
        6540;Y;N
        6550;Y;N
        6560;Y;N
        6570;Y;N
        6600;Y;N
        6610;Y;N
        6620;Y;N
        6630;Y;N
        6640;Y;N
        6650;Y;N
        6660;Y;N
        6670;Y;N
        6700;Y;N
        6710;Y;N
        6720;Y;N
        6730;Y;N
        6740;Y;N
        6750;Y;N
        6760;Y;N
        6770;Y;N       / >
        7402;Y;Y       /HLT
        7404;Y;Y       /OSR
        0             /END OF TABLE

/LIST FOR STATIC IOT TEST. EACH ENTRY CONSISTS OF
/IOT-CODE, SHOULD-SKIP, MAY-CHANGE-AC, (SHOULD-CLEAR-AC).
/THE LAST ELEMENT IS ONLY NEEDED IF MAY-CHANGE-AC IS YES.
IOTLST, 6200;N;N
        CMME;N;N
        RTM;N;Y;N
        SKME;N;N
        SKMM;Y;N
        LTM;N;Y;Y
        LRM;N;Y;Y
        SMME;N;N
        SKME;Y;N
        SKMM;Y;N
        RTM;N;Y;N
        LTM;N;Y;Y
        LRM;N;Y;Y
        0
$